Telecom
General Aviation
RF PA Module
| Band | RF GHz | IF GHz | LO GHz | BW MHz | P-1 dBm | Tx Gain dB | Rx NF | Rx Gain dB |
|---|---|---|---|---|---|---|---|---|
| Ka | 26.5-40 | DC-3 | 26.5-40 | ≤2000 | ≤37 | ≤45 | ≤2.5 | ≥60 |
| K | 18-26.5 | DC-3 | 18-26.5 | ≤2000 | ≤40 | ≤45 | ≤2.0 | ≥60 |
| Ku | 12-18 | DC-2 | 12-18 | ≤1000 | ≤43 | ≤45 | ≤1.5 | ≥60 |
| X | 8-12 | DC-2 | 8-12 | ≤1000 | ≤46 | ≤45 | ≤1.2 | ≥60 |
| <X | 0.5-8 | DC-0.5 | 0.5-8 | ≤1000 | ≤47 | ≤45 | ≤0.8 | ≥60 |
| All Bands | Gain Flatness dB: ±2 (Ka), ±1.5 (K/Ku), ±1 (X/<X) | |||||||
| All Bands | Temperature: -40℃ ~ +80℃ | |||||||
| Remarks | 1. LO can be 1/2, 1/3, or 1/4 of the fundamental. 2. Specification can be customized on request. | |||||||
| RF MHz | BW MHz | Power dBm (PAR 7dB) | Tx Gain dB | Efficiency |
|---|---|---|---|---|
| 800 | 35 | 50 | 45 | 35-48% |
| 900 | 35 | 50 | 45 | 35-48% |
| 1300 | 15 | 47 | 45 | 35-47% |
| 2100 | 60 | 49 | 45 | 35-47% |
| 2600 | 70 | 47 | 45 | 30-40% |
| All Bands | Temperature: -40℃ ~ +80℃ | |||
| Remarks | 1. Power level and efficiency can be adjusted according to PAR. 2. Specification can be customized on request. | |||